TMS zl Management and Configuration Guide ST.1.1.100430
3-69
Initial Setup in Monitor Mode
System Maintenance
Restore to Factory Default Settings (Including IDS/IPS
Signatures)
You can restore the module to the factory default settings by uninstalling then
reinstalling the software image. When you uninstall and reinstall the software,
you will lose all of your IDS/IPS signatures as well as all of your settings. After
restoring factory defaults, you will need to reconfigure your module settings
and download the IDS/IPS signatures again. See “Configure Signature Detec-
tion” in Chapter 6: “Intrusion Detection and Prevention.”
You cannot uninstall and reinstall software from the Web browser interface.
To restore the module to the factory default configuration from the Services
OS context, complete the following steps:
1. Access the Services OS context:
2. Boot the Services OS:
3. When asked if you would like to reboot the module, type
[y].
For example:
hostswitch(services-module-C:PR)# boot service
System will be rebooted. Do you want to continue
[y/n]? y
Rebooting
4. Once the module has rebooted, enter the Services OS context again:
hostswitch# services c 1
5. See which software images are stored on the module.
Syntax: services <slot ID> 1
Enters the Services OS context on the module.
Replace <slot ID> with the letter for the chassis slot in which
the module is installed.
Syntax: boot service
Boots the Services OS.
Syntax: show images
Shows the images that are stored in the image repository.