TMS zl Management and Configuration Guide ST.1.2.100916
3-59
Initial Setup in Monitor Mode
Configuring Event Logging
To enable SNMP traps, do one or both of the following:
■ Select the Enable SNMPv2 traps check box.
■ Select the Enable SNMPv3 traps check box.
Add an SNMPv2 Trap Destination
To add an SNMPv2 trap destination (such as PCM+/NIM), complete the
following steps:
1. Under Enable SNMPv2 traps, click Add another destination. The Add SNMPv2
Destination window is displayed.
Figure 3-36. Add SNMPv2 Destination Window
2. For Server Address, type the IP address or FQDN of an SNMP server. For
example, if you are using PCM+/NIM, you would enter the IP address or
FQDN of the server running PCM+/NIM.
3. For Community Name, type the read-write (unrestricted) community
name.You must enter the read-write community name that is configured
on the SNMP server.
4. Click OK.
5. Click Save.
If you want to add more SNMP v2 trap receivers, repeat these steps. Use the
Edit and Delete icons in the Tools column to modify or remove a trap receiver.
Add an SNMPv3 Trap Destination
To add an SNMPv3 trap destination (such as PCM+/NIM), complete the
following steps:
1. Under Enable SNMPv3 traps, click Add another destination. The Add SNMPv3
Destination window is displayed.