TMS zl Module Release Notes ST.1.2.101122

96
Known Issues
Release ST.1.0.090213
The protocol and the port number of the custom connection timeout should be updated, but they
are not.
PR_15462 — The VLAN name is not checked for special characters. If a VLAN name is
created with special characters, when the VLAN name is displayed in the web browser
interface, problems can occur in the display of the VLAN name. The workaround is to use
alphanumeric VLAN names, avoiding spaces and characters such as: @, #, $, ^, &, *, (, and ).
To include a blank space in a VLAN name, enclose the name in single or double quotes (‘...
or “...”).
PR_15477When adding and removing VLANs via the CLI, additional log messages are
created that are not created when using the web browser interface to add and remove VLANs.
PR_15522There is a difference in how the timezone information is displayed in the TMS
zl Module as compared to the switch. The TMS zl Module follows the POSIX standard for
displaying the time, for example, 'GMT+6' is displayed to indicate the timezone. However,
the switch uses a negative number to set the timezone. The time is correctly displayed in
both cases, but the process to set the timezone may cause some confusion.
PR_16231 — Some log entries for warning logs and information logs have messages that
are truncated in the log viewer. The most log messages are not truncated and those that are
contain enough information that a user can tell what they are about. However, the messages
have more information in them than can be displayed.
PR_16539When using the TMS zl Module CLI, the radius-server help command gives
options that are not available.
PR_16546 — A TMS zl Module that incorrectly has duplicate IP addresses for its VLANs
may cause the TMS zl Module SNMP daemon to restart, which may hide the actual problem
from a user. While it is incorrect to have duplicate IP addresses, this may occur, and the
SNMP daemon restart may send the administrator down the wrong troubleshooting path.
PR_16812When a user incorrectly logs into a TMS zl Module resulting in an
authentication failure, if the TMS zl Module is setup to send traps, it will send an
authentication failure trap. However, the trap does not contain the user's IP address or the
username.
PR_16892When the local log contains more than 10,000 entries, the oldest entries (after
the 1,000th entry) are displayed in a wrong position.
Steps to reproduce:
1. Get more than 10,000 entries in the local log
2. Either export the local log or, in the web browser interface, set the number of entries per
page to 500 and go to page 6.