© Copyright 2007 Hewlett-Packard Development Company, LP. The information contained herein is subject to change without notice. Publication Number Part Number 5991-8624 September 2007 Applicable Product ProCurve Wireless Edge Services zl Module (J9051A) ProCurve Redundant Wireless Services zl Module(J9052A) Trademark Credits Microsoft®, Windows®, and Windows NT® are US registered trademarks of Microsoft Corporation. Adobe® and Acrobat® are trademarks of Adobe Systems Incorporated.
Contents Software Management Software Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Downloading Software and Documentation from the Web . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Downloading Software to the Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Saving Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
iv
Software Management Software Updates Software Management Software Updates Check the ProCurve Networking Web site frequently for software updates for the various ProCurve products you may have in your network. Downloading Software and Documentation from the Web You can download software updates and the corresponding product documentation from ProCurve Networking’s Web site as described below. To Download a Software Version: 1. Go to the ProCurve Networking Web site at: http://www.procurve.com. 2.
Software Management Saving Configurations Downloading Software to the Module C a u ti o n The startup-config file generated by the latest software release is compatible with the same file generated by earlier software releases. HP recommends that you backup your current configuration before performing any software update. See the module’s Management and Configuration Guide (5991-8626) for instructions and more information.
Software Management Saving Configurations Saving the Current Configuration as the Start-Up Configuration When you use the CLI to make a configuration change, the module places the change in the running-config file. If you want to preserve the change across reboots, you must save the change to the startup-config file. Otherwise, the next time the module reboots, the change will be lost. To save configuration changes while using the CLI: 1.
Software Management ProCurve Switch, Routing Switch, and Router Software Keys ProCurve Switch, Routing Switch, and Router Software Keys Software Letter ProCurve Networking Products C 1600M, 2400M, 2424M, 4000M, and 8000M CY Switch 8100fl Series (8108fl and 8116fl) E Switch 5300xl Series (5304xl, 5308xl, 5348xl, and 5372xl) F Switch 2500 Series (2512 and 2524), Switch 2312, and Switch 2324 G Switch 4100gl Series (4104gl, 4108gl, and 4148gl) H Switch 2600 Series, Switch 2600-PWR Series: H.07.
Support Notes Release WT.01.03 Support Notes Release WT.01.03 The Management and Configuration Guide (5991-8626) includes detailed information on the features in software release WT.01.03. To download this guide, see “Downloading Software and Documentation from the Web” on page 1. Accessing the Web Browser Interface — In Case of Difficulty Your web browser or Java cache may trigger problems with initial access to your module.
Support Notes Release WT.01.03 Clear the Internet Explorer (IE) Browser Cache The following steps detail the process of clearing the cache in IE version 6. If you are using a different version, your steps might vary slightly. Follow these steps to clear the cache: 1. Open IE. Figure 1.
Support Notes Release WT.01.03 2. Select Tools > Internet Options. The Internet Options window is displayed. Click this button Figure 2. Tools > Internet Options 3. Make sure that you are in the General tab. 4. In the Temporary Internet files section, click Delete Files. The Delete Files window is displayed. Figure 3. Delete Files 5. 7 Check the Delete all offline content box.
Support Notes Release WT.01.03 6. Click the OK button. 7. In the Internet Options window, click the OK button. Clear the Java Cache The following steps explain how to delete the cache for Sun Java version 1.5 or higher on a Windows XP machine. The steps vary depending on whether your Java version is above or below. See either: ■ “Clear the Cache for Sun Java Versions 1.5 and Higher” on page 8 ■ “Clear the Cache for Sun Java Versions Prior to 1.5” on page 11 Clear the Cache for Sun Java Versions 1.
Support Notes Release WT.01.03 Click this button Figure 5. Java Control Panel 3. 9 In the Temporary Internet Files section, click the Settings button. The Temporary Files Settings window is displayed.
Support Notes Release WT.01.03 Click this button Figure 6. Temporary Files Settings (Java Control Panel) 4. Click the Delete Files button. The Delete Temporary Files window is displayed. Figure 7. Delete Temporary Files (Java Control Panel) 5. Make sure that the Applications and Applets box is checked. 6. Click the OK button. 7. In the Temporary Files Settings window, click the OK button. 8. In the Java Control Panel window, click the OK button.
Support Notes Release WT.01.03 Clear the Cache for Sun Java Versions Prior to 1.5. Follow these steps to delete the Java cache: 1. Select Start > Settings > Control Panel. Java Plug-in Option Figure 8. Control Panel 2. Select Java Plug-in. The Java Plug-in Control Panel window is displayed. Note If your workstation has more than one Java applet, the Control Panel will display multiple Java Plugin options. Complete the following steps for each to ensure that the correct cache is cleared. 3.
Support Notes Release WT.01.03 Click this button Figure 9. Java Plug-in Control Panel 4. You are prompted to confirm clearing the cache. Click the Yes button. Figure 10. Java Plug-in Confirmation Needed Screen 5. Click the Apply button; then close the screen. Restart the Browser You are now ready to access the Wireless Edge Services zl Module’s Web browser interface: 1. Close and re-open your browser. 2. Enter the IP address (or hostname) of your Wireless Edge Services zl Module in the browser. 3.
Support Notes Release WT.01.03 Figure 11. Activate the Java Applet 4. After about a minute, the Login screen is displayed. Figure 12.
Support Notes Release WT.01.03 Configuring Authentication for Web-Users Note Use this section to supplement the information in the chapter “Configuring the ProCurve Wireless Edge Services zl Module” in the Management and Configuration Guide (5991-8626). Instead of (or in addition to) using the local list to authenticate users, you can use a RADIUS server. If the RADIUS server authenticates a user, that user has the rights configured on the RADIUS database.
Support Notes Release WT.01.03 If the server does not send the proper VSAs, the user receives the monitor role (read-only) to the Web browser interface. The module’s internal server does not support VSAs, so you should use the local server only to authenticate users that require read-only access. Note If you do not correctly configure the RADIUS server, you can lock yourself out of the Wireless Edge Services zl Module Web browser interface.
Enhancements Release WT.01.03 Enhancements Unless otherwise noted, each new release includes the enhancements added in all previous releases. WT.01.03 is the first software version for Wireless Edge Services zl Modules. Note The Management and Configuration Guide (5991-8626) provides detailed information on the features in software release WT.01.03. Download this guide for more information. To download this guide, see “Downloading Software and Documentation from the Web” on page 1.
Enhancements Release WT.01.03 Feature Description Secure NTP Configure the module to take its time from an Network Time Protocol (NTP) server, or act as a secure NTP server for other devices. Web-Users accounts Create accounts for Web-Users, allow various levels of access to the module’s Web browser interface. ProCurve Identity Driven Manager (IDM) QoS Supports Quality of Service (QoS) settings created through IDM.
Software Fixes Release WT.01.03 Software Fixes Release WT.01.03 is the first software release for the ProCurve Wireless Edge Services zl Module.
Known Software Issues and Limitations Release WT.01.03 Known Software Issues and Limitations This section identifies issues you may encounter when using a ProCurve Wireless Edge Services zl Module (J9051A) or a ProCurve Redundant Wireless Services zl Module (J9052A). Release WT.01.03 Release WT.01.03 is the first software release for the ProCurve Wireless Edge Services zl Module (J9051A) and the ProCurve Redundant Wireless Services zl Module (J9052A).
Known Software Issues and Limitations Release WT.01.03 ■ Applet (41215) — Since the ability to copy to the running-config has been removed from the web management interface, the system: button should not be displayed on the Management -> System Maintenance - Config File -> Transfer -> browse for location popup window. Workaround: Attempts at transferring to the file provide a meaningful message in the lower left window of the web management interface.
Known Software Issues and Limitations Release WT.01.03 ■ Applet (39807) — There should be an option to generate a Tech-Support file in the web management application, and there is not. Workaround: Generate this file using the CLI command. To do this using TFTP transfer, use the following command syntax. Host_zl_Switch# wireless-services Host_zl_Switch(wireless-services-slot)# support copy tech-support tftp:///
Known Software Issues and Limitations Release WT.01.03 ■ CLI (40893) — The sFlow timeout values that can be configured via the CLI differ from those considered valid by the web management interface. This does not have any significant consequence; values configured in either management context will be honored. ■ CLI (38053) — There is no support for tethereal on the module. Workaround: Use the local or remote mirroring features of the switch to perform packet captures.
Known Software Issues and Limitations Release WT.01.03 ■ Infrastructure (41564) — The Img-File-Ver parameter in the CLI and the corresponding Management -> System Maintenance -> Update Server -> Software version parameter of the web management application are not required values, and they should be. The image file will not be pulled if the version is empty, even if the force-upload parameter is set.
Known Software Issues and Limitations Release WT.01.03 ■ L2-L3 (41737) — Attaching an IP ACL with an allow any ACE to the downlink port stops all the traffic on the downlink, even if there is a MAC extended ACL to explicitly allow ARPs. Workaround: ACLs attached to the downlink port need to explicitly allow the radio port traffic to get through to the module, as shown by a portion of a show run command below.
Known Software Issues and Limitations Release WT.01.03 ■ Security (1000460306) — MAC filter rules are designed to apply to the association process. If a wireless station is already associated, a new “deny” MAC filter configured through Security -> MAC Filter in the web management interface does not take effect until the station re-associates.
Known Software Issues and Limitations Release WT.01.03 ■ Wireless (40983) — Rate limiting is not applied to wireless stations that have roamed or have reconnected to the network if cached PMK is configured. Workaround: Disable PMK caching when vendor specific attributes are required for rate limiting a wireless client (e.g. when using IDM).