Wireless Edge Services zl Module Release Notes WT.01.39

24
Software Fixes
Release WT.01.28
ACL (PR_0000019095) When configuring ACLs in a RADIUS server, if an ACE has a range of ports with spaces
around the hyphen, the server will fail to authenticate the user, even when the ACE is valid.
Web UI (PR_0000018220) Within the Network Setup > Ethernet page, sorting VLANs by selecting the IP Address or
Subnet Mask column headings does not work.
Upgrade (PR_0000017696) After a software upgrade, the WESM displays an “upgrade has been completed”
message, but does not indicate that a WESM reboot is required to complete the upgrade.
Release WT.01.28
Release WT.01.28 is a general release and includes software fixes for all prior releases.
Release WT.01.29
Release WT.01.29 was not a general release.
Problems resolved in Release WT.01.29
Web UI (PR_0000016366) System Name had different restrictions when being set through the Web UI and CLI.
The CLI required a letter as the first character and did not accept spaces in the System Name.
Web UI (PR_000018221) Web UI displays different results from the CLI when the same SNMP Access Control
is configured with two different community names.
CLI (PR_0000018295) When using the same community name, the Web UI functioned correctly but the CLI
would not allow the use of the same community name and displayed the error message: "%Error: Community
string already in use".
Authentication (PR_0000040156) Web User Authentication against an external RADIUS Server does not work
when the 'Number of Retries to communicate with RADIUS Server' value is set to 0.
CLI (PR_0000037878) The 'edit' command under the CLI does not function properly.
System Maintenance (PR_0000017549) When a software image has been upgraded to the WESM and the WESM
has not been reloaded, if a second image is upgraded or the upgrade process is aborted before completion, the WESM
will not be accessible via Web UI or CLI.
Workaround: The WESM module must be removed from the switch chassis and then re-inserted into the chassis, or the
switch must be power cycled.
SNMP (PR_0000017878) Radio description could be incorrectly configured as blank via SNMP.
Web UI (PR_0000040129) Unable to clear the IP address and subnet mask values from any interface when using
the Web UI. The CLI functions correctly.
System (PR_0000041085) Increased the allotted size of log message table.
Authentication (PR_0000001238) The same RADIUS server IP address can be entered multiple times in the
Radius server IP table.
Alarm Log (PR_0000040265) When in the Alarm Log and attempting to display alarm details, the Detail button
generates the following error message: "Failed to get the alarm details. Please retry".
CLI (PR_0000039943) The CLI #diff startup-config running-config command does not display the difference
between the configuration files.
Reports (PR_0000006376) Column titles of the Network Statistics report does not match the labels in the Graphs
and Detailed Information screens.