Wireless/Redundant Edge Services xl Module Management and Configuration Guide WS.01.03 or greater
2-63
Configuring the ProCurve Wireless Services xl Module
SNMP Traps and Error Reporting
SNMP support also enables you to set up alarms on the Wireless Edge Services
xl Module. You simply enable the SNMP traps for the alarms you want to log.
(For more information, see “Enabling SNMP Traps” on page 2-69.)
SNMP Communities
The Wireless Edge Services xl Modules uses the following community names:
■ public
■ private
■ trap
Each community name is assigned an access control, which determines the
operations an SNMP server can complete on the Wireless Edge Services xl
Module:
■ Read-only—The SNMP server can retrieve information from the module.
■ Read-write—The SNMP server can retrieve information and modify the
configuration settings.
By default, the public and trap communities have read-only access, and the
private community has read-write access.
Modifying SNMP Communities
You can modify the public and private communities, but you cannot modify
the trap community. To change the community name or access control setting
for the public or private communities, complete the following steps:
1. From the Management > SNMP Access > v1/v2c screen, select the com-
munity that you want to modify.