ProLiant BL p-Class GbE Interconnect Switch Command Line Interface Reference Guide
Configuring the GbE Interconnect Switch using the Command Line Interface
Configuring Basic GbE Interconnect Switch Information
This section describes how to configure basic GbE Interconnect Switch information.
Setting System Name, Location, and Contact Information
The following shows the factory default settings for system name, system location, and
system contact:
Feature Default Value
System Name None
System Location None
System Contact None
Use the following command to configure the system name, location, and contact information:
Command Description
system set
{
[sysname <system_name>]
[sysloc <system_location>]
[contact <system_contact >]
}
Configures system information
Enter the following in the command:
• sysname <system_name>—Type
sysname and a system name. The
system name can be up to 255
characters in length. Blank spaces are
allowed.
• sysloc <system_location>—Type
sysloc and the system location. The
system location can be up to 255
characters in length. Blank spaces
are allowed.
• contact <system_contact >—Type
contact and the name of the contact
person. HP recommends entering the
name of the person who is responsible
for the maintenance of the network
system on which the GbE Interconnect
Switch is located. The contact name
can be up to 255 characters in length.
Blank spaces are allowed.
Displaying GbE Interconnect Switch Information
You can display basic information about the GbE Interconnect Switch including the type of
switch, any external modules that are installed, and the MAC address (assigned by the factory
and unchangeable) for that GbE Interconnect Switch. In addition, the boot PROM and
firmware version numbers display. This information is helpful in monitoring PROM and
firmware updates.
HP ProLiant BL p-Class GbE Interconnect Switch Command Line Interface Reference Guide 2-9