System Up Time—Identifies the time the switch booted up, if the current time has
been set on the GbE Interconnect Switch. If the current time has never been set up on
the interconnect switch, this field identifies the time since the GbE Interconnect
Switch was booted up.
Time—Displays the current real time set on the GbE Interconnect Switch. If the
current time has never been set up on the interconnect switch, “Unknown” will be
displayed.
Time Source—Displays how the GbE Interconnect Switch obtains the current time:
Primary SNTP Server, Secondary SNTP Server, or System Clock.
Rack #/Name—Displays the rack number and rack name.
Enclosure #/Name—Displays the enclosure number and enclosure name.
System Name—Displays a user-configured name for the GbE Interconnect Switch.
System Location—Displays a user-configured description for the physical location
of the GbE Interconnect Switch.
System Contact—Displays the user-configured name of the person to contact if
there are any problems or questions with the GbE Interconnect Switch.
IMPORTANT: If the GbE Interconnect Switch is booted without an Interconnect Module inserted, the
system show command displays DualTSX Interconnect Module (fiber) information.
This example shows the the advanced switch features.
Auto Logout—Displays the time that the RS-232 console and Telnet management
interface can be idle before the GbE Interconnect Switch automatically logs out the
user. For additional information, refer to the “Configuring Auto-Logout Timer”
section later in this chapter.
HP ProLiant BL p-Class GbE Interconnect Switch Command Line Interface Reference Guide 2-11