ProLiant BL p-Class GbE Interconnect Switch Command Line Interface Reference Guide

Configuring the GbE Interconnect Switch using the Command Line Interface
Adding IGMP Snooping Settings for a VLAN
Use the following command to add IGMP snooping for a VLAN:
Command Description
igmp add
vlan <vlan_id>
state {non | v1 | v2}
robustness <robustness>
interval <query_interval>
response <response>
Adds a VLAN to the IGMP snooping table and
sets the IGMP snooping parameters
Type the following in the command:
vlan <vlan_id>—Type vlan and the VLAN
ID.
state {non | v1 | v2}—Specifies the IGMP
version (V1 or V2) that is used by the IGMP
interface when making queries. Type state
and one of the querier-state options:
non—non-querier
v1—version 1 querier
v2—version 2 querier
robustness <robustness>—Provides a
tuning variable that allows for subnetworks
that are expected to lose a large number of
packets. Type robustness and a value
from 2 to 225, with larger values being
specified for subnetworks that are expected
to lose larger numbers of packets. The
default is 2.
interval <query_interval>—Specifies the
length of time between sending IGMP
queries. Type interval and a value from 1
to 65500 seconds. The default is 125.
response <response>—Sets the maximum
amount of time allowed before sending an
IGMP response report. Type response and
a value from 1 to 25 seconds. The default is
10 seconds.
HP ProLiant BL p-Class GbE Interconnect Switch Command Line Interface Reference Guide 2-21