ProLiant BL p-Class GbE Interconnect Switch Web-based Interface Reference Guide
Configuring the GbE Interconnect Switch using the Web-based Interface
The Rx Packets Analysis window displays the number of bytes and packets received on
the port. The following information is displayed:
•
•
•
•
•
•
•
•
•
•
Time Interval—Select the frequency at which the information on the screen is refreshed.
The setting is between 1s and 60s, where “s” stands for seconds. The default value is
one second.
Record Number—Select the number of times that the GbE Interconnect Switch will be
polled. The setting can be between 20 and 200. The default value is 20.
Bytes—Counts the number of bytes received on the port.
Packets—Counts the number of packets received on the port.
Unicast—Counts the total number of packets that were received by a unicast address.
Multicast—Counts the total number of packets that were received by a multicast address.
Broadcast—Counts the total number of packets that were received by a broadcast
address.
Show/Hide—Select to display or hide bytes and packets information.
Apply—Select to apply any changes made to the Time Interval, Record Number, and
Show/Hide fields.
Clear—Select to reset the counters.
Monitoring Unicast, Multicast, and Broadcast (RX) Packets
To monitor unicast, multicast, and broadcast (UMB) packets, select UMB-cast (RX) Packets
from the Packets menu. The following screens are displayed.