ProLiant BL p-Class GbE Interconnect Switch Web-based Interface Reference Guide

Configuring the GbE Interconnect Switch using the Web-based Interface
The Tx Error Analysis window displays the number of errors that occurred during
transmission. The following information is displayed:
Time Interval—Select the frequency at which the information on the screen is refreshed.
The setting can be between 1s and 60s, where “s” stands for seconds. The default value
is one second.
Record Number—Select the number of times the GbE Interconnect Switch will be
polled. This setting can be between 20 and 200. The default value is 20.
ExDefer—Counts the number of frames for which the first transmission attempt on a
particular interface was delayed because the medium was busy.
LateColl—Counts the number of times that a collision is detected later than 512 bit-
times into the transmission of a packet.
ExColl—Counts the number of frames that experienced 16 collisions during transmission
and were aborted.
SingColl—Counts the number frames that experienced exactly one collision during
transmission.
Coll—Counts the number of collisions that occurred during the transmission of a frame.
Show/Hide—Select to display or hide ExDefer, LateColl, CRCError, SingColl, and Coll
errors.
Apply—Select to apply any changes made to the Time Interval, Record Number, and
Show/Hide fields.
Clear—Select to reset the counters.
2-56 HP ProLiant BL p-Class GbE Interconnect Switch Web-based Interface Reference Guide