ProLiant BL p-Class GbE2 Interconnect Switch Browser-based Interface Reference Guide

Configuring the switch 127
Switch Port ACL Meter Configuration
To display the following form, go to the Switch Port Configuration form. Select an ACL meter number.
The following table describes the Switch Port ACL Meter Configuration controls:
Table 101 Switch Port ACL Meter Configuration controls
Control Description
Committed rate (1000-1000000 kb/s) Configures the committed rate, in Kilobits per second. The committed rate must be
a multiple of 64.
Maximum burst Size (32-4096 kb/s) Configures the maximum burst size, in Kilobits. Enter one of the following values
for
mbsize: 32, 64, 128, 256, 512, 1024, 2048, 4096
Set out of profile to Drop or Pass Configures the ACL Meter to either drop or pass out-of-profile traffic.
Enable Enables or disables the ACL meter.
ACLs Available Lists the ACLs that you can add to the meter.