ProLiant BL p-Class GbE2 Interconnect Switch Browser-based Interface Reference Guide
Configuring the switch 201
Uplink Failure Detection Configuration
To display the following form, select Uplink Failure Detection (click the underlined text, not the folder).
Uplink Failure Detection (UFD) supports network fault tolerance in network adapter teams. Use this menu to
configure a Failure Detection Pair of one Links to Monitor (LtM) group and one Links to Disable (LtD) group. When
UFD is enabled and a Failover Pair is configured, the switch automatically disables ports in the LtD if it detects a
failure in the LtM. The failure conditions which are monitored in the LtM group include port link state moving to
down, or port state moving to Blocking if Spanning Tree Protocol is enabled.
The following table describes the Uplink Failure Detection (UFD) configuration controls:
Table 180 Uplink Failure Detection Configuration controls
Control Description
UFD state Globally turns UFD on or off.
FDP Displays the Failure Detection Pair Configuration form.