The following table describes the ACL Group Configuration commands.
Table 164 ACL Group Configuration commands
Command Description
access-control group <1-4096> list
<1-4096>|block <1-4096>
Adds the selected ACL or ACL Block to the ACL Group.
Command mode: Global configuration
no access-control group <1-4096>
list <1-4096>|block <1-4096>
Removes the selected ACL or ACL Block from the ACL Group.
Command mode: Global configuration
show access-control group <1-4096> Displays the current ACL group parameters.
Command mode: All except User EXEC
Remote Monitoring configuration
Remote Monitoring (RMON) allows you to monitor traffic flowing through the switch. The RMON MIB is described in
RFC 1757.
The following table describes the basic RMON Configuration commands. The following sections provide more
detailed information and commands.
Table 165 RMON commands
Command Description
show rmon Displays the current RMON configuration.
Command mode: All
RMON history configuration
The following table describes the RMON History commands.
Table 166 RMON History commands
Command Description
rmon history <1-65535> interface-oid
<1-127 characters>
Configures the interface MIB Object Identifier. The IFOID must
correspond to the standard interface OID, as follows:
1.3.6.1.2.1.2.2.1.1.x
The interface OID can have a maximum of 127 characters.
Command mode: Global configuration
rmon history <1-65535> requested-
buckets <1-65535>
Configures the requested number of buckets, which is the number
of discrete time intervals over which data is to be saved.
The range is from 1 to 65535. The default is 30.
Note: The maximum number of buckets that can be granted
is 50.
Command mode: Global configuration
rmon history <1-65535> polling-
interval <1-3600>
Configures the time interval over which the data is sampled for
each bucket.
The range is from 1 to 3600 seconds. The default value is 1800
seconds.
Command mode: Global configuration
rmon history <1-65535> owner <1-127
characters>
Enter a text string that identifies the person or entity that uses this
history index.
The owner can have a maximum of 127 characters.
Command mode: Global configuration
no rmon history <1-65535> Deletes the selected history group.