ProLiant BL p-Class GbE2 Interconnect Switch ISCLI Reference Guide
Configuration Commands 137
Port-based port mirroring
The following table describes the port-based Port Mirroring Configuration commands.
Table 170 Port Mirroring Configuration commands
Command Description
port-mirroring monitor-port <port
number> mirroring-port <port number>
{in|out|both}
Adds the port to be mirrored. This command also allows you
to enter the direction of the traffic. It is necessary to specify
the direction because:
• If the source port of the frame matches the mirrored port
and the mirrored direction is ingress or both (ingress and
egress), the frame is sent to the mirrored port.
• If the destination port of the frame matches the mirrored
port and the mirrored direction is egress or both, the
frame is sent to the monitoring port.
Command mode: Global configuration
no port-mirroring monitor-port <port
number> mirroring-port <port number>
Removes the mirrored port.
Command mode: Global configuration
no port-mirroring monitor-port <port
number>
Deletes this monitored port.
Command mode: Global configuration
show port-mirroring Displays the current settings of the monitoring port.
Command mode: All except User EXEC
Uplink Failure Detection configuration
Uplink Failure Detection (UFD) supports network fault tolerance in network adapter teams. Use these commands to
configure a Failure Detection Pair of one Links to Monitor (LtM) group and one Links to Disable (LtD) group. When
UFD is enabled and a Failure Detection Pair is configured, the switch automatically disables ports in the LtD if it
detects a failure in the LtM. The failure conditions which are monitored in the LtM group include port link state moving
to down, or port state moving to Blocking if Spanning Tree Protocol is enabled.
The following table describes the Uplink Failure Detection (UFD) Configuration commands.
Table 171 Uplink Failure Detection Configuration commands
Command Description
ufd enable Globally turns Uplink Failure Detection ON.
Command mode: Global configuration
no ufd enable Globally turns Uplink Failure Detection OFF.
Command mode: Global configuration
show ufd Displays the current Uplink Failure Detection configuration parameters.
Command mode: All
Failure Detection Pair configuration
Use these commands to configure a Failure Detection Pair, which consists of one Link to Monitor (LtM) and one Link to
Disable (LtD). When the switch detects a failure on the LtM, it automatically disables the ports in the LtD.
The following table describes the Failure Detection Pair (FDP) configuration commands.
Table 172 Failure Detection Pair Configuration commands
Command Description
ufd fdp enable Enables the FDP Parameters.
Command mode: Global configuration
no ufd fdp enable Disables the FDP Parameters.
Command mode: Global configuration