ProLiant BL p-Class GbE2 Interconnect Switch ISCLI Reference Guide

Information Commands 24
System information
The following command displays system information:
show sys-info
Command mode: All
System Information at 17:29:18 Mon Feb 26, 2007
HP ProLiant BL p-Class C-GbE2 Interconnect Switch B
sysName: 2JUnit1
sysLocation: Houston
RackID: 3334KJP3D030
RackName: BkRm3
Enclosure: D304JTK7D013
EnclosureName: Enterprise
Slot: B
Switch is up 1 days, 2 hours, 3 minutes and 40 seconds.
Last boot: 17:25:38 Mon Feb 26, 2007 (software reset)
MAC address: 00:01:81:2e:ae:e0 IP (If 2) address: 10.30.52.193
Revision: 0A
Switch Serial No: K72550AQKP1863
Hardware Part No: 336181-001 Spare Part No: 321148-001
Interconnect Module Part Number : 283192-B21 Spare Part Number:
321147-001
OctalFC Interconnect Module not present
Software: Version 3.2.0 (FLASH image1), active configuration
System information includes:
System date and time
Switch model name and number
HP c-Class Rack name and location
Time of last boot
MAC address of the switch management processor
IP address of the switch
Software image file and version number
Current configuration block (active, backup, or factory default)
Login banner, if one is configured