ProLiant BL p-Class GbE2 Interconnect Switch ISCLI Reference Guide

Information Commands 29
LACP dump
The following command displays LACP information:
show lacp information
Command mode: All
>> LACP# dump
port lacp adminkey operkey selected prio attached trunk
aggr
----------------------------------------------------------------------
1 off 1 1 n 32768 -- --
2 off 2 2 n 32768 -- --
3 off 3 3 n 32768 -- --
4 off 4 4 n 32768 -- --
5 off 5 5 n 32768 -- --
6 off 6 6 n 32768 -- --
7 off 7 7 n 32768 -- --
8 off 8 8 n 32768 -- --
LACP dump includes the following information for each port in the GbE2 Interconnect Switch:
lacp—Displays the port’s LACP mode (active, passive, or off).
adminkey—Displays the value of the port’s adminkey.
operkey—Shows the value of the port’s operational key.
selected—Indicates whether the port has been selected to be part of a Link Aggregation Group.
prio—Shows the value of the port priority.
attached aggr—Displays the aggregator associated with each port.
trunk—This value represents the LACP trunk group number.
Hot Links Trigger information
The following command displays Hot Links information:
show hotlinks information
Command mode: All
Hot Links Info: Trigger
Current global Hot Links setting: ON
sndfdb disabled
Current Trigger 1 setting: enabled
Name “Corporate Uplinks”, preempt disabled, fdelay 1 sec
Active state: None
Master settings:
port 20
Backup settings:
port 21
Hot Links Trigger information includes the following information:
Operational status (on or off)
FDB Update status (enabled or disabled)
Trigger configuration
Trigger state