ProLiant BL p-Class GbE2 Interconnect Switch ISCLI Reference Guide
Information Commands 29
LACP dump
The following command displays LACP information:
show lacp information
Command mode: All
>> LACP# dump
port lacp adminkey operkey selected prio attached trunk
aggr
----------------------------------------------------------------------
1 off 1 1 n 32768 -- --
2 off 2 2 n 32768 -- --
3 off 3 3 n 32768 -- --
4 off 4 4 n 32768 -- --
5 off 5 5 n 32768 -- --
6 off 6 6 n 32768 -- --
7 off 7 7 n 32768 -- --
8 off 8 8 n 32768 -- --
…
LACP dump includes the following information for each port in the GbE2 Interconnect Switch:
• lacp—Displays the port’s LACP mode (active, passive, or off).
• adminkey—Displays the value of the port’s adminkey.
• operkey—Shows the value of the port’s operational key.
• selected—Indicates whether the port has been selected to be part of a Link Aggregation Group.
• prio—Shows the value of the port priority.
• attached aggr—Displays the aggregator associated with each port.
• trunk—This value represents the LACP trunk group number.
Hot Links Trigger information
The following command displays Hot Links information:
show hotlinks information
Command mode: All
Hot Links Info: Trigger
Current global Hot Links setting: ON
sndfdb disabled
Current Trigger 1 setting: enabled
Name “Corporate Uplinks”, preempt disabled, fdelay 1 sec
Active state: None
Master settings:
port 20
Backup settings:
port 21
Hot Links Trigger information includes the following information:
• Operational status (on or off)
• FDB Update status (enabled or disabled)
• Trigger configuration
• Trigger state