HP ProLiant BL e-Class Integrated Administrator User Guide

Command Line Interface
Table 4-8: Functionality Exclusive to the Command Line Interface continued
Function Description Capability Exclusive to the
Command Line Interface
Enclosure Management Commands, continued
REBOOT BAY
<bay number>
{[ , | - ]
<bay number>}
{FORCE} {[PXE
| HDD | RBSU]}
Sends a request to the server blade
to perform a graceful shutdown.
The server blade is then powered
on. If no server blade is in the
specified bay, the user is told that
the bay is empty.
The optional boot arguments require
a BIOS version of 06/15/02 or
greater of the ProLiant BL10e Server
blade ROM.
Adding an optional boot argument
with force the blade to abandon the
regular boot order and force a boot
using the specified method.
Allows for optional boot argument
SET BAY BOOT
FIRST [HDD |
PXE] <bay
number> {[ , |
- ] <bay
number>}
Sets the IPL for each subsequent
reboot. This setting is only valid for
present blades and is cleared if a
blade is removed.
This command requires BIOS
version 06/15/02 or greater for the
ProLiant BL10e server blade ROM.
Only enclosures and
administrators may execute this
command.
SET BAY BOOT
ONCE [HDD |
PXE | RBSU]
<bay number>
{[ , | - ]
<bay number>}
Sets the boot device to be used on
the next boot of the bay(s) specified.
This setting is only valid on present
blades and is cleared if the blade is
removed.
This command requires BIOS
version 06/15/02 or greater for the
ProLiant BL10e server blade ROM.
Only enclosure and
administrators may execute this
command.
continued
4-34 HP ProLiant BL e-Class Integrated Administrator User Guide
HP CONFIDENTIAL
Writer: Amy Clute File Name: e-ch4 Command Line Interface.doc
Codename: Halo Part Number: 249070-004 Last Saved On: 6/16/03 9:27 AM