HP ProLiant BL e-Class Integrated Administrator User Guide

Command Line Interface
Enclosure Management Commands
Table 4-5: Enclosure Management Commands
Command Description Restrictions
CLEAR SYSLOG
ENCLOSURE
Clears the enclosure system log Only enclosure administrators
may execute this command.
Once deleted, this information
cannot be restored.
POWEROFF
ENCLOSURE
{FORCE}
Performs a graceful shutdown of the
enclosure. Each blade is first gracefully
shutdown. If the FORCE argument is
given, the enclosure and all blades are
immediately shutdown.
Only enclosure administrators
may execute this command.
RESTART
Restarts the Integrated Administrator.
This does not affect current operation
of bays in the system.
Only enclosure administrators
may execute this command.
SET DATE
MMDDhhmm
{{CC}YY} {TZ}
Sets the date of the enclosure with the
following definitions:
MM: month
DD: day
hh: hour (24-hour time)
mm: minute
CC: century
YY: year
TZ: time zone (case-sensitive)
If the time zone is left blank, the
current time zone is left in effect.
Only enclosure administrators
may execute this command.
MM is an integer from 1-12.
DD is an integer from 1-31.
hh is an integer from 0-23.
mm is an integer from 0-59.
For a list of time zones, see
Appendix F, “Time Zone
Settings.”
NTP must be disabled before
manually setting the date and
time.
continued
4-16 HP ProLiant BL e-Class Integrated Administrator User Guide
HP CONFIDENTIAL
Writer: Amy Clute File Name: e-ch4 Command Line Interface.doc
Codename: Halo Part Number: 249070-004 Last Saved On: 6/16/03 9:27 AM