Server agents 102
Symptom: The DC-DC Power Converter condition has been set to degraded for the specified chassis,
slot, and socket.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHePwrConvChassis
cpqHePwrConvSlot
cpqHePwrConvSocket
Supporting SNMP Trap Description: “The Power Converter Degraded on Chassis
[cpqHePwrConvChassis], Slot [cpqHePwrConvSlot], Socket [cpqHePwrConvSocket].”
NT Event ID: 1138 (Hex)0xc4350472 (cpqsvmsg.dll)
Log Severity: Error (3)
Log Message: The DC-DC power converter is in a failed state. Replace the power converter.
SNMP Trap: cpqHe3PowerConverterFailed - 6044 in CPQHLTH.MIB
Symptom: The DC-DC Power Converter condition has been set to failed for the specified chassis, slot,
and socket.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHePwrConvChassis
cpqHePwrConvSlot
cpqHePwrConvSocket
Supporting SNMP Trap Description: “The Power Converter Failed on Chassis
[cpqHePwrConvChassis], Slot [cpqHePwrConvSlot], Socket [cpqHePwrConvSocket].”
NT Event ID: 1139 (Hex)0x84350473 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The DC-DC power converter is in a failed state. Replace System Information Agent:
Health: The DC-DC Power Converter sub-system has lost redundancy. Replace any failed or degraded
power converters.
SNMP Trap: cpqHe3PowerConverterRedundancyLost - 6045 in CPQHLTH.MIB
Symptom: The DC-DC Power Converters have lost redundancy for the specified chassis.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHePwrConvChassis
Supporting SNMP Trap Description: “The Power Converters are no longer redundant on Chassis
[cpqHePwrConvChassis].”
NT Event ID: 1140 (Hex)0x84350474 (cpqsvmsg.dll)
Log Severity: Warning (2)