Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25

Server agents 103
Log Message: Hot Plug PCI Board Removed. A hot plug PCI adapter has been removed from the
system.
SNMP Trap: cpqSiHotPlugSlotBoardRemoved - 2008 in CPQSINFO.MIB
Symptom: Hot Plug Slot Board Removed. A Hot Plug Slot Board has been removed from the specified
chassis and slot.
User Action: None.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSiHotPlugSlotChassis
cpqSiHotPlugSlotIndex
Supporting SNMP Trap Description: “Hot Plug Slot Board Removed from Chassis
[cpqSiHotPlugSlotChassis], Slot [cpqSiHotPlugSlotIndex].”
NT Event ID: 1141 (Hex)0x44350475 (cpqsvmsg.dll)
Log Severity: Information (1)
Log Message: Hot Plug PCI Board Inserted. A hot plug PCI adapter has been inserted into the system.
SNMP Trap: cpqSiHotPlugSlotBoardInserted - 2009 in CPQSINFO.MIB
Symptom: Hot Plug Slot Board Inserted. A Hot Plug Slot Board has been inserted into the specified
chassis and slot.
User Action: None.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSiHotPlugSlotChassis
cpqSiHotPlugSlotIndex
Supporting SNMP Trap Description: “Hot Plug Slot Board Inserted into Chassis
[cpqSiHotPlugSlotChassis], Slot [cpqSiHotPlugSlotIndex].”
NT Event ID: 1142 (Hex)0xc4350476 (cpqsvmsg.dll)
Log Severity: Error (3)
Log Message: Hot Plug PCI Board Failed. A hot plug PCI adapter has failed to power up. Insure the
board and all cables are installed correctly.
SNMP Trap: cpqSiHotPlugSlotPowerUpFailed - 2010 in CPQSINFO.MIB
Symptom: Hot Plug Slot Board Failed Power-Up. A Hot Plug Slot Board has failed to power up in the
specified chassis and slot.
User Action: Be sure the board and all cables are installed correctly, and that the board type and
revision are the same as the replaced board.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSiHotPlugSlotChassis