Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25

Server agents 117
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “Inadequate power to power on blade
[cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack
[cpqRackName].”
NT Event ID: 1168 (Hex)0x84350490 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Server Power On Via Manual Override
Log Message: Server power on via manual override.
SNMP Trap: cpqRackServerPowerOnManualOverride - 22026 in CPQRACK.MIB
Symptom: Server power on via manual override. The server blade was powered on by a manual
override.
User Action: None.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackServerBladeEnclosureName
cpqRackServerBladePosition
cpqRackServerBladeSparePartNumber
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “Server power on via manual override on blade
[cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack
[cpqRackName].”
NT Event ID: 1169 (Hex)0x84350491 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Fuse or Breaker Tripped
Log Message: The fuse has been tripped.
SNMP Trap: cpqRackFuseOpen - 22027 in CPQRACK.MIB
Symptom: Fuse open. The fuse has been tripped.
User Action: Check enclosure and blade power connections and reset the fuse.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackCommonEnclosureName
cpqRackCommonEnclosureFuseLocation
cpqRackCommonEnclosureSparePartNumber