Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25
Storage agents 39
Log Severity: Warning (2)
Event Title: Storage System Side Panel Removed.
Log Message: The side panel has been removed on the %6 %7 storage system connected to SCSI bus
%5 of the controller in slot %4.
SNMP Trap: cpqSs3SidePanelRemoved - 8013 in CPQSTSYS.MIB
Symptom: Storage System side panel is removed. The side panel status has been set to removed. The
storage system's side panel is not in a properly installed state. This situation may result in improper
cooling of the drives in the storage system due to air flow changes caused by the missing side panel.
User Action: Replace the storage system side panel.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqSsBoxSidePanelStatus
Supporting SNMP Trap Description: “Side panel is removed from unit.”
NT Event ID: 1102 (Hex)0x4435044e (cpqstmsg.dll)
Log Severity: Information (1)
Event Title: Storage System Side Panel In Place.
Log Message: The side panel has been replaced on the %6 %7 storage system connected to SCSI bus
%5 of the controller in slot %4.
SNMP Trap: cpqSs3SidePanelInPlace - 8012 in CPQSTSYS.MIB
Symptom: Storage System side panel is in place. The side panel status has been set to in place. The
storage system's side panel has returned to a properly installed state.
User Action: None.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqSsBoxSidePanelStatus
Supporting SNMP Trap Description: “Side panel is re-installed on unit.”
NT Event ID: 1104 (Hex)0x84350450 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Fault Tolerant Power Supply Degraded.
Log Message: The fault tolerant power supply in the %6 %7 storage system connected to SCSI bus %5
of the controller in slot %4 has a degraded status. Restore power or replace any failed power supply.
SNMP Trap: cpqSs4PwrSupplyDegraded - 8015 in CPQSTSYS.MIB
Symptom: A storage system power supply status has been set to degraded.
User Action: Restore power or replace any failed storage system power supply.
Supporting SNMP Trap Data:
• sysName