Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25
Storage agents 43
• cpqFcaPhyDrvModel
• cpqFcaPhyDrvSerialNum
• cpqFcaPhyDrvFWRev
• cpqFcaPhyDrvFailureCode
Supporting SNMP Trap Description: “Status is now [cpqFcaPhyDrvStatus] for a physical drive on bus
[cpqFcaPhyDrvBusNumber], bay [cpqFcaPhyDrvBay].”
NT Event ID: 1147 (Hex)0xc435047b (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Spare Drive Status Change.
Log Message: The spare drive in port %5, bay %6 on array “%4” has a new status of %7.
SNMP Trap: cpqFcaSpareStatusChange - 16002 in CPQFCA.MIB
Symptom: External Array Spare Drive Status Change. This trap indicates that the agent has detected a
change in the status of an External Channel Array spare drive. The variable cpqFcaSpareStatus
indicates the current spare drive status. The variable cpqFcaSpareBusNumber indicates the SCSI bus
number associated with this drive.
User Action: If the spare drive status is failed, replace the drive.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqSsChassisName
• cpqSsChassisTime
• cpqFcaSpareBusNumber
• cpqFcaSpareBay
• cpqFcaSpareStatus
Supporting SNMP Trap Description: “Spare Status is now [cpqFcaSpareStatus] on bus
[cpqFcaSpareBusNumber].”
NT Event ID: 1148 (Hex)0xc435047c (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Accelerator Status Change.
Log Message: The array accelerator board attached to the external controller in I/O slot %5 of array
“%4” has a new status of %6.
SNMP Trap: cpqFca2AccelStatusChange - 16017 in CPQFCA.MIB
Symptom: External Array Accelerator Board Status Change. This trap indicates that the agent has
detected a change in the status of an Array Accelerator Cache Board. The current status is
represented by the variable cpqFcaAccelStatus.
User Action: If the accelerator board status is permDisabled(5), you may need to replace the
accelerator board.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags