Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25

Server agents 96
Supporting SNMP Trap Description: “Remote Insight mouse cable disconnected.”
NT Event ID: 1117 (Hex)0x8435045d (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Remote Insight Board has detected that the external power cable is disconnected.
SNMP Trap: cpqSm2ExternalPowerCableDisconnected - 9010 in CPQSM2.MIB
Symptom: External Power Cable Disconnected. The Remote Insight external power cable has been
disconnected.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
Supporting SNMP Trap Description: “Remote Insight external power cable disconnected.”
NT Event ID: 1118 (Hex)0x4435045e (cpqsvmsg.dll)
Log Severity: Information (1)
Log Message: The Fault Tolerant Power Supply Sub-system has been returned to the OK state.
SNMP Trap: cpqHe4FltTolPowerSupplyOk - 6048 in CPQHLTH.MIB
Symptom: The fault tolerant power supply condition has been set back to the OK state for the
specified chassis and bay location.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeFltTolPowerSupplyChassis
cpqHeFltTolPowerSupplyBay
cpqHeFltTolPowerSupplyStatus
cpqHeFltTolPowerSupplyModel
cpqHeFltTolPowerSupplySerialNumber
cpqHeFltTolPowerSupplyAutoRev
cpqHeFltTolPowerSupplyFirmwareRev
cpqHeFltTolPowerSupplySparePartNum
cpqSiServerSystemId
Supporting SNMP Trap Description: “The Power Supply is OK on Chassis
[cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay], Status
[cpqHeFltTolPowerSupplyStatus], Model [cpqHeFltTolPowerSupplyModel], Serial Num
[cpqHeFltTolPowerSupplySerialNumber], Firmware [cpqHeFltTolPowerSupplyFirmwareRev].”
NT Event ID: 1123 (Hex)0x84350463 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: Post Errors were detected. One or more Power-On-Self-Test errors were detected during
server startup.
SNMP Trap: cpqHe3PostError - 6027 in CPQHLTH.MIB
Symptom: One or more POST errors occurred. Power On Self-Test (POST) errors occur during the
server restart process.