HP Scripting Toolkit 9.60 for Windows User Guide

Comment or clarificationError messageError code
An error occurred during the configuration process, but HP
SSA cannot identify the error because there is an internal HP
SSA error.
Internal error.516
This error message occurs if you attempt to add an odd
number of drives to an array that has RAID 1 logical drives,
and the controller does not support RAID-level migration.
Array requires an odd number of drives.1052
This error message occurs if a script that is running in
Reconfigure action mode lists fewer physical drives than
Cannot remove physical drives from
existing array.
1053
already exist in the array. HP SSA interprets this script as a
request to remove physical drives from an existing array, but
satisfying this request causes data loss, so HP SSA prevents
the script from running.
HP SSA does not support multiple simultaneous expansions,
migrations, or extensions without saving the configuration
Too many coinciding expansion, migration,
or extension operations.
1065-1066
between operations. Limit the number of such configuration
changes in the script.
Controller does not support SSP.1091
Controller requires physical drives to set
license keys.
1093
You cannot run a script in Input mode on internal controllers
that do not have slot information online. Systems running
Slot information is not available.1102
Microsoft Windows must have the System Management Driver
loaded.
Controller does not support license keys.1110
Invalid license key.1111
Controller has maximum number of license
keys.
1112
Controller requires non-failed physical
drives to set license keys.
1114
Controller is locked by another machine or
user.
2564
The scripted Method value is not valid.Invalid Method.2818
The scripted controller does not match any existing controllers.Invalid Controller.2819
Could not detect controller <text>.2820
This error applies to Input mode only. If no controllers are
detected in Capture mode, the capture file is empty.
No controllers detected.2821
The specified cache ratio is not supported by either the
controller or the current controller configuration.
Invalid read cache/write cache ratio.2822
Invalid rebuild priority.2823
This error message appears if the expand priority value
specified in the script is not supported. This message also
Invalid expand priority.2824
appears if expansion is not possible because the Expand
Priority feature is then not supported. Expansion might be
temporarily unavailable on a controller that normally supports
expansion if, for example, the cache battery has low charge,
another expansion or migration is already in progress, or the
array has the maximum supported number of physical drives.
The array ID is invalid.Invalid array.2825