Viewing Overlay Details
If you double-click on a flash overlay, another window appears with details about that overlay.
Figure 101: Overlay Detail window
To see the details of a different flash overlay image, you can either close the details window and double-
click on another overlay name, or choose a different overlay name from the Flash overlay menu.
Viewing the PCI Registers
The PCI Registers appear directly on the Diagnostics tab.
Running a Quick Test
The Diagnostics tab enables you to run a “quick” diagnostics test on a selected adapter. The Quick Test
consists of 50 PCI Loopback test cycles and 50 Internal Loopback test cycles. (Not available in read-
only mode or on LightPulse adapters in ESXi hosts.)
To use quick test:
1. From the discovery-tree, select the adapter port on which you want to run the Quick Test.
2. Select the Diagnostics tab and click Quick Test. A warning message appears.
Figure 102: Quick Test Warning
3. Click OK to run the test. The Quick Diagnostic Test window appears displaying the PCI
Loopback and Internal Loopback test results.
Note: Internal and External Loopback tests are not available for LP2100 and LP21002
adapters.