The OneCommand Manager User Manual Page 175
Error Action
Enables you to define what is to be done in the event of a test failure. There are two error action options:
Stop Test - Do not log the error and abort the test. No further tests are run.
Ignore - Log the error and proceed with the next test cycle.
Test Cycles
Enables you to specify test cycles three ways:
Select an established cycle count by clicking on the corresponding radio button.
Enter a custom cycle count in the blank field in the Test Cycles area.
Set the test to run until you manually click Stop Test, by selecting the Infinite radio button.
Test Pattern
Enter a custom test pattern to be used in tests that transfer data. The test pattern can be up to 8
hexadecimal bytes.
Test Status
The Test Status area displays how many completed cycles of each test ran, as well as the number of
errors.
To run loopback tests:
1. From the discovery-tree, select the adapter port on which you want to run the Loopback Test.
2. Select the Diagnostics tab and click Advanced Diagnostics Tests. From the Loopback Test
section of the dialog box, choose the type of Loopback test you want to run and define the
loopback test parameters.
3. Click Start. The following warning appears:
Figure 106: Run Diagnostic Tests Warning
4. Click OK. If you choose to run an External Loopback test the following window appears:
Note: You must insert a loopback plug in the selected adapter before running an External
Loopback test.