Emulex Driver for Linux and OneCommand Manager Application Situations
Unwanted remote servers appear in the
OneCommand Manager application.
To prevent remote servers from appearing in the OneCommand
Manager application, do one of the following on the remote
systems:
• In Windows, disable the OneCommand Manager application
service.
• In Linux, stop the elxhbamgr daemon by running the
/usr/sbin/ocmanager/stop_ocmanager script.
• In Solaris, stop the elxhbamgr service by issuing the
command "svcadm disable elxhbamgr".
Disabling this service or process prevents the local servers
from being seen remotely.
Running a dump command on LP9002
adapters using TCP/IP based management
causes error "ERROR: <302>".
Run the command in-band or locally on these adapters.
Table 7: Emulex Driver for Linux and OneCommand Manager Application Situations
Situation Resolution
FC link fails to come up. For LP21000 adapters, ensure the adapter is not in
maintenance mode and that it is not running the manufacturing
firmware.
NIC Link fails to come up. For Emulex OneConnect OCe1010X adapters, you may need to
properly configure the network interface using system
administration utilities.
The OneCommand Manager application
software package will not install. An error
message states that: “inserv Service Elxlpfc
has to be enabled for service
ElxDiscSrvinserv: exiting now/sbin/ inserv
failed exit code 1.”
Reinstall the driver with the lpfc-install script.
If a SAN configuration has 256 targets
mapped by the LPFC driver, any additional
added targets do not get a target ID mapping
by the driver and cause target discovery to
fail. Removing targets or reinitializing the link
does not solve the problem.
Unload and reload the driver to reset available target IDs.
Ensure that the SAN configuration is correct prior to reloading
the driver. This will clear the driver’s consistent binding table
and free target IDs for new target nodes.
In some cases, after loading an OEM
supplied combined firmware/OpenBoot
image you will not be able to enable
BootBIOS from the lputil Boot BIOS
Maintenance menu.
1. Download the current OpenBoot only image for your adapter
from the Emulex website.
2. Load the current OpenBoot only image following steps listed
in Updating BootBIOS section of this manual.
3. Run lputil, return to the Boot BIOS Maintenance menu.
4. Enable BootBIOS.
Table 6: General Situations (Continued)
Situation Resolution