Emulex OneCommand Manager Application User Manual (P006979-01A Version 5.2, August 2011)

The OneCommand Manager User Manual Page 81
3. Select the Maintenance tab.
Figure 44: FC Maintenance tab
Maintenance Tab Field Definitions
Firmware Area
Current Version - The Emulex firmware version number for this model of adapter.
Initial Load - The firmware version stub responsible for installing SLI code into its proper slot.
(Not available on VMware ESX servers being managed through the CIM interface.)
SLI-2 Name - The name of the SLI-2 firmware overlay. (Not available on VMware ESX servers
being managed through the CIM interface.)
Kernel Version - The version of the firmware responsible for starting the driver. (Not available on
VMware ESX servers being managed through the CIM interface.)
Operational Name - The name of the operational firmware for the selected adapter. (Not
available on VMware ESX servers being managed through the CIM interface.)
SLI-1 Name - The name of the SLI-1 firmware overlay. (Not available on VMware ESX servers
being managed through the CIM interface.)
SLI-3 Name - The name of the SLI-3 firmware overlay. (Not available on VMware ESX servers
being managed through the CIM interface.)
Adapter Boot Version - Displays one of the following:
The selected adapter port's boot code version if boot code is present.
“Disabled” if the boot code is disabled.