HP Smart Update Manager 6.3.1 Release Notes (Ed. 2)

HP SUM 6.x does not configure Insight Management SNMP Agent components
Suggested Action: HP SUM applies the default configuration settings for the component. Review and
update the Insight Management SNMP Agents after HP SUM finishes installing the component.
HP SUM does not save configuration settings for SNMP components
Suggested Action: Configure SNMP settings outside of HP SUM and then copy the components to the
baseline.
HP SUM does not configure SMH component when using an input file
Suggested Action: No action. This will be resolved in a future version.
Component logs for iLO firmware displays incorrect details
Suggested Action: No action. This will be resolved in a future version.
HP SUM displays “Update returned an error when deploying 32-bit Linux components to 64-bit Linux
nodes
Suggested Action: Install the 32-bit versions of the dependency libraries. For more information, see
“Prerequisites (page 4).
HP SUM displays an error on a ProLiant DL580 Gen8 server
Suggested Action: For information on this issue, see the Customer Advisory at http://
h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c04127124.
HP SUM on Windows 2012 systems displays two versions of some Windows 2012 components
Suggested Action: When running on Windows 2012, if HP SUM displays two versions of a component,
HP SUM is displaying the Windows 2012 and Windows 2012 R2 components. Click Available
Version and read the information to determine which version of the component to apply.
HP SUM displays “Update returned an error when deploying the HP ProLiant Converged Network
Utility for Windows 2008 (component cp022111.exe)
Suggested Action: No action. This will be resolved in a future version of the component.
HP SUM reports that component cp0205354.exe does not update if you Force or Rewrite it when
deploying to an HP ProLiant MicroServer
Suggested Action: No action. Deploy this component outside of HP SUM.
CLI issues
The /use_web legacy CLI command does not work
Suggested Action: Use the GUI mode to download baselines from hp.com. Once HP SUM downloads
the baseline, you can use CLI mode to perform updates using the downloaded baseline.
HP SUM does not deploy multiple components in legacy CLI mode when listed separately in one
command
Suggested Action: Copy the components into a directory and use the /use_location command. If
you are deploying more than ten components, use this suggested action.
Report issues
HP SUM does not display VMware Smart Array firmware components on firmware reports
Suggested Action: No action. This is a known issue that will be resolved in a future version.
Issues and suggested actions 21