HP Smart Update Manager 6.0.1 Release Notes (Ed. 3)

HP SUM Console mode displays an error when you add the localhost by IP address
Suggested Action: No action. When you add the localhost to HP SUM in console mode by IP address,
it displays an error adding the IP address. The localhost can only be added by specifying the name,
localhost.
Viewing logs after deploying updates in offline mode
Suggested Action: Run gatherlogs in the HP SUM directory function from a write-able directory.
HP SUM does not update firmware in offline mode when memory is greater than 1 terrabyte
Suggested Action: No action necessary. This will be resolved in a future version.
HP SUM displays a return code of 6 for Flash Backed Write Cache for B-Series Smart Array firmware
Suggested Action: If the return code is 6, HP SUM cannot update this component. No action necessary.
HP SUM displays “Update returned an error” when deploying the HP Fibre Channel Enablement Kit
for Linux
Suggested Action: View the update log. If you see the error Enablement kit is not supported
for the installed driver version, use the following instructions to work around this issue:
1. Install HBA drivers before installing the Enablement kit.
2. Make sure the driver and Enablement kit version match.
This known issue will be resolved in a future version.
Deploying updates to OA and iLO nodes at the same time might cause a network issue
Suggested Action: Deploy updates to the iLO and OA through the OA node. HP SUM determines the
proper deployment order to minimize deployment issues. Alternatively, you can wait for HP SUM to
finish updating one node and then update the other node.
HP SUM requires minimum versions of VC and OA to support HP Integrity nodes
Suggested Action: Verify that HP Integrity i2 OA versions are 3.30 and VC version 3.6, and HP Integrity
i4 servers are OA version 3.60 and VC version 3.70.
HP SUM stops responding during inventory on IPv6 networks
Suggested Action: Use IPv4 addresses for VC nodes. Use VCSU to update VC nodes if no IPv4 addresses
are available.
HP SUM displays the iLO firmware version as 0.0.0 for Linux nodes
Suggested Action: Make sure that the CHIF driver is installed so HP SUM can detect the correct iLO
firmware version. This applies to iLO2, iLO3, and iLO4.
HP SUM does not install iLO firmware updates when TPM is active
Suggested Action: Disable TPM if HP SUM does not apply iLO updates.
HP SUM does not reboot a node after deploying updates in HP SUM offline interactive mode
Suggested Action: Reboot the server in the HP SPP offline environment.
HP SUM in GUI mode does not display the firmware or software you chose after pressing analyzing
groups
Suggested Action: Select all options for nodes individually, not as a group.
20 Issues and suggested actions