HP BladeSystem c-Class Enclosure Troubleshooting Guide

HP BladeSystem Insight Display troubleshooting 23
Step HP BladeSystem c7000 Enclosure Insight Display action and verification
Verification
Wait for up to 2 minutes, and then check the Insight Display.
If the issue still exists, then continue to the next step.
If the Insight Display illuminates and the Insight Display buttons operate, then complete
the repair by replacing the original OA tray.
To replace the OA tray:
1 Install the metal cover.
2 Install the devices in the original device bays.
3 Remove OA #X from OA bay X.
4 Remove the spare OA tray.
5 Install the original OA tray.
6 Install OA #X in OA bay X.
7 Install OA #Y, if present.
Step 13
Contact an authorized service provider to complete the midplane assembly replacement
(on page 66).