HP ProLiant BL495c Server Blade Installation Instructions

Interconnect bay numbering and device
mapping
HP BladeSystem c7000 Enclosure
To support network connections for specific signals, install an
interconnect module in the bay corresponding to the embedded
NIC or mezzanine signals.
Server blade
signal
Interconnect bay Interconnect bay labels
Flex-10 NIC 1
(embedded)
1
Flex-10 NIC 2
(embedded)
2
Mezzanine 1 3 and 4
Mezzanine 2 5 and 6
7 and 8
For detailed port mapping information, see the HP BladeSystem
enclosure installation poster or the HP BladeSystem enclosure setup
and installation guide on the HP website
(http://www.hp.com/go/bladesystem/documentation
).
HP BladeSystem c3000 Enclosure and Tower Enclosure
Server blade
signal
Interconnect
bay number
Interconnect
bay label
Notes
Flex-10 NIC 1,
2 (embedded)
1
Mezzanine 1 2
Four port cards
connect to bay 2
Mezzanine 2 3,4
Four port cards
Ports 1 and 3
connect to bay 3
Ports 2 and 4
connect to bay 4
For detailed port mapping information, see the HP BladeSystem
enclosure installation poster or the HP BladeSystem enclosure setup
and installation guide on the HP website
(http://www.hp.com/go/bladesystem/documentation
).
Connecting to the network
To connect the HP BladeSystem to a network, each enclosure must
be configured with network interconnect devices to manage
signals between the server blades and the external network.
Two types of interconnect modules are available for HP
BladeSystem c-Class enclosures: Pass-thru modules and switch
modules. For more information about interconnect module options,
see the HP website
(http://www.hp.com/go/bladesystem/interconnects
).
Installing a server blade
CAUTION: To prevent improper cooling and thermal
damage, do not operate the server blade enclosure unless
all bays are populated with either a component or a
blank.