d. Remove the divider from the enclosure.
Installing interconnect modules
For specific steps to install interconnect modules, see the
documentation that ships with the interconnect module.
Interconnect bay numbering and device
mapping
HP BladeSystem c7000 Enclosure
HP BladeSystem c3000 Enclosure
To support network connections for specific signals, install an
interconnect module in the bay corresponding to the embedded
adapter or mezzanine signals.
Server
blade signal
c7000
interconnect
bay
c3000
interconnect
bay
Interconnect
bay labels
FlexFabric
adapter 1
(Embedded)
1 1
FlexFabric
adapter 2
(Embedded)
2 1
FlexFabric
adapter 3
(Embedded)
1 1
FlexFabric
adapter 4
(Embedded)
2 1
FlexFabric
adapter 5
(Embedded)
1 1
FlexFabric
adapter 6
(Embedded)
2 1
Mezzanine
1
3 and 4 2
Mezzanine
2
5 and 6* 3 and 4
7 and 8** 3 and 4
Mezzanine
3
5 and 6** 3 and 4
7 and 8* 3 and 4
Mezzanine
4
5 and 6** 3 and 4
7 and 8* 3 and 4
Mezzanine
5
3 and 4 2
Mezzanine
6
1 and 2
1
Mezzanine
7
5 and 6* 3 and 4
7 and 8** 3 and 4
* Dual port mezzanine card ports and four-port mezzanine card
ports 1 and 2
** Four-port mezzanine card ports 3 and 4
Dedicated dual-port Ethernet mezzanine
For detailed port mapping information, see the HP BladeSystem
enclosure installation poster or the HP BladeSystem enclosure setup
and installation guide on the HP website
(http://www.hp.com/go/bladesystem/documentation
).
Connecting to the network
To connect the HP BladeSystem to a network, each enclosure must
be configured with network interconnect devices to manage signals