HP ProLiant Gen8 Troubleshooting Guide Volume I: Troubleshooting

Diagnostic flowcharts 34
The server blade is not configured to automatically power on in HP iLO.
The power being supplied is not sufficient for the server blades installed in the enclosure.
The power cap is not configured properly for the enclosure.
The OA module is not properly installed in the enclosure.
A possible communication failure between HP iLO and the OA is causing the server blade to wait for
permission to power on.
The server blade has a mismatched fabric installed on the mezzanine 1 connector or the mezzanine 2
connector.
On Intel-based HP ProLiant Gen8 server blades, the health status LED bar flashes red in a repeating pattern
when certain errors occur. In the Server blade power-on problems flowchart for HP ProLiant Gen8 Intel Server
Blades, the patterns are abbreviated as follows:
Long Short Short Off (LSS)
Long Short Long Off (LSL)
Short Long Short Off (SLS)
Short Short Long Off (SSL)