HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP Smart Array errors 112
FR_CHKBLK_FAILED_WRITE - Drive failed write command while checking for media
errors.
FR_ATI_TEST_FAILED_WRITE - Drive failed write command while checking for
errors.
OFFLINE_ERASE - Drive is offline due to a Secure Erase operation.
OFFLINE_TOO_SMALL - Drive is offline because it’s a replacement drive that
is too small.
OFFLINE_DRIVE_TYPE_MIX - Drive is offline because it is not the correct type
for this array [SATA vs SAS].
OFFLINE_ERASE_COMPLETE - Drive is offline because a Secure Erase operation
has completed on it but it hasn’t been replaced yet.
Message Id: 24596
Severity: Error
Log message: The <drive type> physical drive located in bay <bay number> is in a
SMART predictive failure state. This drive can be found in box <box number> which
is connected to port <port number> of the array controller <controller name /
slot information>.
Message Id: 24597
Severity: Warning
Log message: The <drive type> physical hard drive located in bay <bay number> is
not supported <not supported reason>. This drive can be found in box <box number>
which is connected to port <port number> of the array controller <controller name
/ slot information>.
<not supported reason> values:
because it is a singled ported drive
because it is a SATA drive
because it is smaller than the drive it is replacing
because it is of an unrecognized type
because it contains an unsupported RIS configuration
Message Id: 24598
Severity: Informational
Log message: Logical drive <logical drive number> of array controller <controller
name / slot information> has encountered a status change from:
Status: <previous status>
to
Status: <current status>
<previous status> and <current status> values:
OK
FAILED
NOT CONFIGURED