HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP Smart Array errors 115
Message Id: 24602
Severity: Warning
Log message: The recovery of logical drive <logical driver number> configured on
array controller <controller name / slot information> was aborted while
rebuilding due to an unrecoverable read error. Physical drive number <physical
drive number> was the replacement drive being rebuilt before the read error
occurred, while physical drive number <physical drive number> is the error drive
which reported the read error.
Message Id: 24603
Severity: Warning
Log message: Due to an unrecoverable read error, the recovery of logical drive %3
configured on array controller <controller name / slot information> was aborted
while rebuilding a physical drive.
The physical drive which was being rebuilt is located in bay <bay number> of box
<box number> which is connected to port <port number> of array controller
<controller name / slot information>.
The physical drive that reported the read error is located in bay <bay number>
of box <box number> which is connected to port <port number> of array controller
<controller name / slot information>.
Message Id: 24604
Severity: Warning
Log message: The recovery of logical drive <logical drive number> configured on
array controller <controller name / slot information> was aborted while
rebuilding due to an unrecoverable write error. Physical drive number <physical
drive number> was the replacement drive being rebuilt before the write error
occurred, while physical drive number <physical drive number> is the error drive
which reported the write error.
Message Id: 24605
Severity: Warning
Log message: Due to an unrecoverable write error, the recovery of logical drive
<logical drive number> configured on array controller <controller name / slot
information> was aborted while rebuilding a physical drive.
The physical drive which was being rebuilt is located in bay <bay number> of box
<box number> which is connected to port <port number> of array controller
<controller name / slot information>.
The physical drive that reported the write error is located in bay <bay number>
of box <box number> which is connected to port <port number> of array controller
<controller name / slot information>.
Message Id: 24606
Severity: Error
Log message: Logical drive <logical drive number> configured on array controller
<controller name / slot information> returned a fatal error during a read/write
request from/to the volume.
Logical block address <lba number>, block count <bc number> and command <command
number> were taken from the failed logical I/O request.