HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP Smart Array errors 117
Severity: Informational
Log message: Array controller <controller name / slot information> has reported that
the external array controller attached to port <port number> has been disconnected
or powered down.
Message Id: 24615
Severity: Informational
Log message: Array controller <controller name / slot information> has reported that
an external array controller was attached to port <port number> or was previously
attached and was powered on.
Message Id: 24616
Severity: Warning
Log message: Array controller <controller name / slot information> is reporting that
an unsupported configuration has occurred with the redundant cabling that is
attached between port <port number> and box <box number>. <firmware information>.
Please check the cabling and ensure that a supported configuration is being used.
<firmware information> values:
The Smart Array firmware is reporting that no additional details are
available
The Smart Array firmware is reporting that the redundant cabling
configuration on the controller has a mix of storage boxes with and without
redundant I/O modules
The Smart Array firmware is reporting that a redundant I/O paths exist due
to direct loopback of the controller ports
The Smart Array firmware is reporting that the redundant I/O modules of this
box are not cabled for good fault tolerance
The Smart Array firmware is reporting that the redundant I/O modules of this
box have multiple paths to the controller
Message Id: 24617
Severity: Warning
Log message: Array controller <controller name / slot information> is reporting that
an unsupported configuration has occurred with the redundant cabling that is
attached to port <port number>. <firmware information>. Please check the cabling
and ensure that a supported configuration is being used.
<firmware information> values:
The Smart Array firmware is reporting that no additional details are
available”
The Smart Array firmware is reporting that the redundant cabling
configuration on the controller has a mix of storage boxes with and without
redundant I/O modules
The Smart Array firmware is reporting that a redundant I/O paths exist due
to direct loopback of the controller ports
The Smart Array firmware is reporting that the redundant I/O modules of this
box are not cabled for good fault tolerance