HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP Smart Array errors 146
Log message: The MSA chassis labeled as <chassis label> has reported that battery
pack number <battery pack number> located on controller number <controller
number> has been <inserted / removed>.
The external Smart Array controller reporting this operation is attached to the
host side Smart Array controller <controller name / slot information>.
Message Id: 24766
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting that the <drive type> physical hard drive located
in bay <bay number> is in a SMART predictive failure state.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24767
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that more physical devices were detected than
the controller is currently capable of supporting. Some physical drives will not
be accessible.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24768
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that the storage enclosure attached to port <port
number> with chassis serial number <serial number> has had power supply number
<power supply number> <inserted / removed>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24769
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan number <fan number> located on fan module
<fan module number> was <inserted / removed>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24770
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that fan number <fan number> located on fan module
<fan module number> has failed. The external Smart Array controller may attempt
to shut down power and/or spin down the installed disk drive(s).
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24771