HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

Microsoft Windows Event ID and SNMP traps 292
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqFcaCntlrBoxIoSlot
cpqFcaCntlrStatus
cpqFcaCntlrModel
cpqFcaCntlrSerialNumber
cpqFcaAccelTotalMemory
Supporting SNMP Trap Description: “Status is now [cpqFcaCntlrStatus].”
NT Event ID: 1152 (Hex)0x84350480 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Fan Module Status Change.
Log Message: Storage system “%4” fan module at location %5 has a new status of %6.
SNMP Trap: cpqSsEx2FanStatusChange - 8020 in CPQSTSYS.MIB
Symptom: Storage system fan status change. The agent has detected a change in the fan module status of a
storage system. The variable cpqSsFanModuleStatus indicates the current fan status.
User Action: If the fan status is degraded or failed, replace any failed fans.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqSsFanModuleLocation
cpqSsFanModuleStatus
cpqSsFanModuleSerialNumber
cpqSsFanModuleBoardRevision
Supporting SNMP Trap Description: “Storage system fan status changed to [cpqSsFanModuleStatus].”
NT Event ID: 1153 (Hex)0x84350481 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Power Supply Status Change.
Log Message: Storage system “%4” power supply in bay %5 has a new status of %6.
SNMP Trap: cpqSsEx2PowerSupplyStatusChange - 8021 in CPQSTSYS.MIB
Symptom: Storage system power supply status change. The agent has detected a change in the power supply
status of a storage system. The variable cpqSsPowerSupplyStatus indicates the current status.
User Action: If the power supply status is failed, restore power or replace the failed power supply.