HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 30
Array Accelerator: The cache is disabled because a capacitor has failed to charge to
an acceptable level.
Action: Replace the capacitor.
Array Accelerator: The cache is disabled because the backup operation to flash
memory failed.
Action: Reseat the controller cache module. If the problem persists, contact HP support ("HP contact
information" on page 393).
Array Accelerator: The cache is disabled because there are no capacitors attached
to the cache module.
Action: Install a capacitor.
Array Accelerator: The cache is disabled because a flash memory or capacitor
hardware failure has been detected.
Action: Contact HP support ("HP contact information" on page 393).
Array Accelerator: This controller's firmware is not backward compatible with the
cache module revision.
Action: Upgrade the controller to the latest firmware. If the problem persists, contact HP support ("HP contact
information" on page 393).
Array status: The array has failed.
Action: Check for failed physical or logical drives in the array and correct the failure cause.
Array status: The array currently has a drive erase operation queued, running,
stopped or completed on a logical or physical drive.
Action: No action is required.
Array Status: The array has a spare drive assigned which is smaller than the smallest
data drive in the array…
…Some operations in the array will not be available.
Action: Replace the spare drive with another drive at least the size of the smallest data drive in the array.
Controller State: The array controller contains a volume that was created with a
different version of controller firmware
…and is not backward-compatible with the current version of firmware. You may reconfigure the controller, but the
existing configuration and data will be overwritten and potentially lost.