HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

Microsoft Windows Event ID and SNMP traps 340
Log Severity: Error (3)
Log Message: A memory board or cartridge bus error has been detected in the memory subsystem.
SNMP Trap: cpqHe5ResMemBoardBusError- 6067 in CPQHLTH.MIB
Symptom: Memory board, cartridge, or riser bus error detected. An Advanced Memory Protection
sub-system board, cartridge, or riser bus error has been detected. Value 0 for CPU means memory is not
processor-based.
User Action: Replace the indicated board or cartridge or Riser.
SNMP Trap Data:
sysName,
cpqHoTrapFlags
cpqHeResMem2BoardSlotNum
cpqHeResMem2BoardCpuNum
cpqHeResMem2BoardRiserNum
Supporting SNMP Trap Description: “Memory Board or Cartridge Inserted into Slot
[cpqHeResMem2BoardSlotNum], Cpu[cpqHeResMem2BoardCpuNum],
Riser[cpqHeResMem2BoardRiserNum].”
NT Event ID: 1039 (Hex) 0x8435040FL (cpqsvmsg.dll)
Log Severity: Warning (3)
Log Message: The Advanced Memory Protection sub-system has detected a memory fault. The LockStep
recovery engine has been activated. For instruction on replacing the faulty memory, see the server
documentation.
SNMP Trap: cpqHeResilientMemLockStepMemoryEngaged - 6068 in CPQHLTH.MIB
Symptom: Advanced Memory Protection LockStep Engine Memory Engaged. The Advanced Memory
Protection subsystem has detected a memory fault. The LockStep engine has been activated.
User Action: Replace the faulty memory.
Supporting SNMP Trap Data:
sysName,
cpqHoTrapFlags
Supporting SNMP Trap Description: “The Advanced Memory Protection subsystem has engaged the
LockStep memory.”
NT Event ID: 1040 (Hex) 0xC43504A0L (cpqsvmsg.dll)
Log Severity: Warning (3)
Log Message: The fault tolerant power supply AC power loss for the specified chassis and bay location.
SNMP Trap: cpqHeResilientMemLockStepMemoryEngaged - 6069 in CPQHLTH.MIB
Symptom: The fault tolerant power supply AC power loss for the specified chassis and bay location.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags