HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

Microsoft Windows Event ID and SNMP traps 371
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “Inadequate power to power on blade [cpqRackServerBladePosition],
in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName].”
NT Event ID: 1167 (Hex)0xc435048f (cpqsvmsg.dll)
Log Severity: Error (3)
Event Title: Inadequate Power To Power On
Log Message: There is not enough power to power on the server blade. The power enclosure micro-controller
was not found.
SNMP Trap: cpqRackServerPowerOnFailedPowerChassisNotFound - 22025 in CPQRACK.MIB
Symptom: Inadequate power to power on. There is not enough power to power on the server blade. The
power enclosure micro-controller was not found.
User Action: Check power enclosure connections or add power supplies.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackServerBladeEnclosureName
cpqRackServerBladePosition
cpqRackServerBladeSparePartNumber
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “Inadequate power to power on blade [cpqRackServerBladePosition],
in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName].”
NT Event ID: 1168 (Hex)0x84350490 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Server Power On Via Manual Override
Log Message: Server power on via manual override.
SNMP Trap: cpqRackServerPowerOnManualOverride - 22026 in CPQRACK.MIB
Symptom: Server power on via manual override. The server blade was powered on by a manual override.
User Action: None.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName