HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 79
1762-Slot X Drive Array - Controller Firmware Upgrade Needed
...(Unsupported Cache Module Attached)
....Caching is disabled.
Audible Beeps: None
Possible Cause: The current controller firmware does not support the attached cache module type.
Action: Upgrade the controller firmware, or replace the cache module.
1762-Slot X Drive Array - Controller Firmware Upgrade Needed
...(Unsupported Array Accelerator Attached)
Audible Beeps: None
Possible Cause: The current controller firmware does not support the attached Array Accelerator module
type.
Action: Upgrade the controller firmware, or replace the Array Accelerator module.
1763-Slot X Drive Array - Array Accelerator module is detached; please reattach.
Audible Beeps: None
Possible Cause: Array accelerator module is loose, missing, or defective.
Action:
1. Reseat array accelerator module.
2. If the problem persists, replace the array accelerator module.
1763-Slot X Drive Array - Array Accelerator daughtercard critical error; please
replace...
...(Controller is disabled until this problem is resolved)
Audible Beeps: None
Possible Cause: Array accelerator module is loose, missing, or defective.
Action: Replace the array accelerator module.
1764-Slot X Drive Array - Capacity Expansion Process is Temporarily Disabled...
(followed by one of the following:)
...Expansion will resume when Cache Module has been reattached.
* Expansion will resume when Cache Module has been replaced.
* Expansion will resume when Cache Module RAM allocation is successful.
* Expansion will resume when Battery Pack/Super-Cap reaches full charge.
* Expansion will resume when Automatic Data Recovery has been Completed.
* Expansion will resume when Battery Pack/Super-Cap is connected.
Audible Beeps: None
Possible Cause: The capacity expansion process has been temporarily disabled.
Action: Follow the action that is displayed onscreen to resume the capacity expansion process.