HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 81
* Expansion Progress Data Could Not Be Read From Array Accelerator.
* Expansion Aborted due to Unrecoverable Drive Errors.
* Expansion Aborted due to Array Accelerator Errors.
Select "F1" to continue with logical drives disabled
Select "F2" to accept data loss and to re-enable logical drives
Audible Beeps: None
Possible Cause: Data was lost while the array was expanded; therefore, the drives have been temporarily
disabled. Capacity expansion failed due to:
Array accelerator or hard drive failed or was removed; expansion progress data lost
Expansion progress data could not be read from array accelerator
Expansion aborted due to unrecoverable drive errors
Expansion aborted due to array accelerator errors
Action:
Press the F1 key to continue with the logical drives disabled. Or, press the F2 key to accept the data loss
and re-enable the logical drives.
Restore data from backup.
Replace drive or array accelerator, as appropriate.
1770-Slot X Drive Array - Disk Drive Firmware Update Recommended - ...
...Please upgrade firmware on the following drive model(s) using ROM Flash Components (download from
www.hp.com/support/proliantstorage): Model XYZ (minimum version = ####)
Audible Beeps: None
Possible Cause: Drive firmware update needed.
Action: The indicated drives are running firmware that is known to cause intermittent problems. Update all
drives to the latest firmware version.
1774-Slot X Drive Array - Obsolete data found in Cache Module...
...Data Found in Cache Module was Older Than Data Found on Drives. Obsolete Data has been Discarded
Audible Beeps: None
Possible Cause: Drives were used on another controller and reconnected to the original controller while data
was in the original controller cache. Data found in the cache module is older than data found on the drives
and has been automatically discarded.
Action: Check the file system to determine whether any data has been lost.
1774-Slot X Drive Array - Obsolete data found in Array Accelerator...
...Data Found in Array Accelerator was Older Than Data Found on Drives. Obsolete Data has been Discarded
Audible Beeps: None
Possible Cause: Drives were used on another controller and reconnected to the original controller while data
was in the original controller cache. Data found in the array accelerator is older than data found on the
drives and has been automatically discarded.
Action: Check the file system to determine whether any data has been lost.