HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 94
**001 of 010**
---caution---
03/19/2002
12:54 PM
FAN INSERTED
Main System
Location:
System Board
Fan ID: 03
**END OF EVENT**
WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary
information in the server documentation before removing, replacing, reseating, or modifying
system components.
IMPORTANT: This guide provides information for multiple servers. Some information may not
apply to the server you are troubleshooting. Refer to the server documentation for information on
procedures, hardware options, software tools, and operating systems supported by the server.
NOTE: The error messages in this section may be worded slightly different than as displayed by
the server.
A CPU Power Module (System Board, Socket X)...
...A CPU Power Module (Slot X, Socket Y) Failed
Event Type: Power module failure
Action: Replace the power module. In the case of an embedded power module, replace the system board.
ASR Lockup Detected: Cause
Event Type: System lockup
Action: Examine the IML to determine the cause of the lockup. For more information, refer to the HP
ROM-Based Setup Utility User Guide on the server Documentation CD or the SmartStart Support and
Documents website (http://www.hp.com/support/smartstart/documentation).
Automatic operating system shutdown initiated due to fan failure
Event Type: Fan failure
Action: Replace the fan.
Automatic Operating System Shutdown Initiated Due to Overheat
Condition...
...Fatal Exception (Number X, Cause)
Event Type: Overheating condition
Action: Check fans. Also, be sure the server is properly ventilated and the room temperature is set within the
required range.