Table 23 POST Error Messages
Error code Error message Description/corrective action
048h Password check failed
Password is incorrect after retried a few times. Users might need to
reset the password.
04Ch
Keyboard/Interface
Error
Keyboard controller failed test. This may indicate a problem with
system hardware.
05Dh
S.M.A.R.T. Status
BAD, Backup and
Replace
Hard Disk S.M.A.R.T feature test fail ,indicate a problem with hard
disk
05Eh Password check failed
If user input incorrect password more than three times, then display
this error information and continue to boot.
110h
Un-correctable DRAM
ECC Error detected at
cpuXX/DIMM0X
(cpu01/DIMM08)
Detect multi-bit error in the DIMM prompt, press F1 continue to boot
201h
Memory Data Error –
Jx, DIMM x
Jx, x- corresponding to 1, 2, 3, 4,…8 and 10,11…17
DIMM x – corresponding to 1, 2, 3…8
613h
Power supplies
mismatch, replace
slot#2 with identical
Power supply
Press F1 to continue
booting with one
power supply
When two power supplies installed, if their vendor are different, this
will appear and system will halt.
604h System Fan 1 Missing
If system fan1 is not installed or failed, system will announce this
message and system will shutdown in minutes.
605h System Fan 2 Missing
If system fan2 is not installed or failed, system will announce this
message and system will shutdown in minutes.
606h System Fan 3 Missing
If system fan3 is not installed or failed, system will announce this
message and system will shutdown in minutes.
607h System Fan 4 Missing
If system fan4 is not installed or failed, system will announce this
message and system will shutdown in minutes.
608h
Fan Solution Not
Sufficient!
Critical Failure
Detected - System
Shutting Down in xx
seconds!
If one or more fan are missing, this message will appear with 'system
fan x missing' together.