HP ProLiant DL320 Generation 5 Server Maintenance and Server Guide
Diagnostic tools 64
2. Power down the server (on page 26).
3. Insert the ROMPaq diskette.
4. Set S1, S4, S5, and S6 of the system maintenance switch to On.
5. Power up the server.
o If the diskette is valid, the server generates two short beeps to indicate that the server is in
disaster recovery mode.
o If the diskette is invalid or not inserted, the server continues to beep.
6. Wait while the ROMPaq diskette flashes the system ROM image:
o If successful, the server generates a sequence of descending audible beeps.
o If unsuccessful, the server generates two short beeps. Repeat the disaster recovery process.
7. Power down the server (on page 26).
8. Remove the ROMPaq diskette.
9. Set S1, S4, S5, and S6 of the system maintenance switch to Off.
10. Power up the server.