Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25
Server agents 110
• cpqRackName
• cpqRackUid
• cpqRackCommonEnclosureName
• cpqRackCommonEnclosureSerialNum
• cpqRackCommonEnclosureFanLocation
• cpqRackCommonEnclosureFanSparePartNumber
• cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] fan in rack
[cpqRackName] has been inserted.”
NT Event ID: 1155 (Hex)0xc4350483 (cpqsvmsg.dll)
Log Severity: Error (3)
Event Title: Rack Power Supply Failed
Log Message: This trap indicates that a power supply has failed.
SNMP Trap: cpqRackPowerSupplyFailed - 22013 in CPQRACK.MIB
Symptom: The power supply status has been set to failed. This trap indicates that a power supply has
failed.
User Action: Replace the power supply as soon as possible.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqRackName
• cpqRackUid
• cpqRackPowerSupplyEnclosureName
• cpqRackPowerSupplySerialNum
• cpqRackPowerSupplyPosition
• cpqRackPowerSupplyFWRev
• cpqRackPowerSupplySparePartNumber
• cpqRackCommonEnclosureSerialNum
• cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The power supply [cpqRackPowerSupplyPosition] in enclosure
[cpqRackPowerSupplyEnclosureName] in rack [cpqRackName] has been set to failed.”
NT Event ID: 1156 (Hex)0x84350484 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Rack Power Supply Degraded
Log Message: This trap indicates that a power supply has degraded.
SNMP Trap: cpqRackPowerSupplyDegraded - 22014 in CPQRACK.MIB
Symptom: The power supply status has been set to degraded. This trap indicates that a power supply
has degraded.
User Action: Replace the power supply as soon as possible.